Class: ResourceParameterType

timapi.constants.ResourceParameterType()

Overview

Members-Overview

new ResourceParameterType()

Parameter type

Classifies the value of the tag.

The following values are valid:

Guides: petrol, dialog.

Member-List

activeReaders (static, constant)

Defines which card readers are active during the dialog. This is a bitmap. Value 0 = reader not active, 1 = reader active.
Example 1: Only magstripe reader active = 00000001 = 01 hex
Example 2: Only contactless reader active = 00000100 = 04h
Example 3: Magstripe, chip and contactless reader active = 00000111 = 07h

  • Bit 1: Magstripe reader
  • Bit 2: Chip reader
  • Bit 3: Contactless reader
  • Bit 4: RFU
  • Bit 5: RFU
  • Bit 6: RFU
  • Bit 7: RFU
  • Bit 8: RFU
This value is to be transmitted hex encoded. Example: For a value of 00000111 (Magstripe, Chip and Ctless active), the value '07' hex must be transmitted.

Specification: petrol.

codeCheckData (static, constant)

Data used in the calculation of some CodeCheckType s. This value is to be encoded as hex string.

Specification: petrol.

codeCheckKeyId (static, constant)

Key id of the key to use for the selected CodeCheckType .

  • 0: Tokheim key id.
  • 1: HecPAC key id.
  • 2: DASAG key id.
  • 3: Diplomatkarten key id.
  • 4: Micrelec key id
  • 5000: Start of test key range.
  • 5002: DASAG test key id.
This value is to be encoded as a ascii number i.e. using characters in the range 30h to 39h.

Specification: petrol.

codeCheckType (static, constant)

Type of code check to perform.

  • 0: EMV - Check using EMV PIN check.
  • 1: SwissPost - SwissPost Card algorithm.
  • 2: Avia - Use Aviacard algorithm.
  • 3: SB - Use Scheit & Bachmann algorithm.
  • 4: ProEDA/Tokheim - Use ProEDA / Tokheim algorithm
  • 5: Agrola - Use Agrola algorithm
  • 6: Bica - Use Bica algorithm
  • 7: CTAC - Use CTAC algorithm
  • 8: DASAG - Use DASAG algorithm
  • 9: DKV - Use DKV algorithm
  • 10: Esso - Use Esso algorithm
  • 11: Migrol - Use Migrol algorithm
  • 12: Oelpool - Use Oelpool algorithm
  • 13: Pronto - Use Pronto algorithm
  • 14: Shell - Use Shell algorithm
  • 15: WLDC - Use WLDC algorithm
  • 16: Hectronic - Use HecPAC algorithm
  • 17: Diplomatkarte - Use Diplomatkarten algorithm
  • 18: Micrelec - Use the Micrelec algorithm
  • 19: Schenk - Use the Schenk algorithm
  • 20: BeBeCo - Use the BeBeCo (Postbetriebe) algorithm
This value is to be encoded as a ascii number i.e. using characters in the range 30h to 39h.

Specification: petrol.

exponent (static, constant)

Currency Exponent e.g. to define input mask for Amount entry. n2 value
Example 1: Exponent = 2 will result in an input mask of XXXX.XX with 2 positions after decimal point.
Example 2: Exponent = 3 will result in an input mask of XXX.XXX with 3 positions after decimal point.

Specification: petrol.

keyModeF1 (static, constant)

Mode of function key 1. Determines how the terminal handles the key pressed event of function key 1. Valid values are:

  • DISABLED
    : Do not show the function key. No action if the key is pressed.
  • INTERRUPT
    : Default. The key interrupts the InitTransaction process. The press is reported through the ReasonCode.
  • NOTIFY
    : The key does not interrupt the InitTransaction process. The press is reported through a KeyPress Notification.

Specification: petrol.

keyModeF2 (static, constant)

Mode of function key 2. Determines how the terminal handles the key pressed event of function key 2. Valid values are:

  • DISABLED
    : Do not show the function key. No action if the key is pressed.
  • INTERRUPT
    : Default. The key interrupts the InitTransaction process. The press is reported through the ReasonCode.
  • NOTIFY
    : The key does not interrupt the InitTransaction process. The press is reported through a KeyPress Notification.

Specification: petrol.

keyModeF3 (static, constant)

Mode of function key 3. Determines how the terminal handles the key pressed event of function key 3. Valid values are:

  • DISABLED
    : Do not show the function key. No action if the key is pressed.
  • INTERRUPT
    : Default. The key interrupts the InitTransaction process. The press is reported through the ReasonCode.
  • NOTIFY
    : The key does not interrupt the InitTransaction process. The press is reported through a KeyPress Notification.

Specification: petrol.

petrolCardData1 (static, constant)

Track 1 of a petrol card. This value is to be encoded as a ascii string.

Specification: petrol.

petrolCardData2 (static, constant)

Track 2 of a petrol card. This value is to be encoded as a ascii string.

Specification: petrol.

petrolCardData3 (static, constant)

Track 3 of a petrol card. This value is to be encoded as a ascii string.

Specification: petrol.

pinRetryCounter (static, constant)

Defines how many times a PIN or other code entry can be done before failing the dialog.
Example: PinRetryCounter = 3, the PIN (or other code) can be entered 3 times in total before the dialog fails.

Specification: petrol.

regularData (static, constant)

Customer data of the regular.

Specification: petrol.

regularDataQueryType (static, constant)

Type of query to receive data about regulars.

  • StfkV1: Version 1 regular data query type in Austria.
  • StfkV4: Version 4 regular data query type in Austria.
This value is to be encoded as a ascii string.

Specification: petrol.